This cable is suitable for control, signal transmission, monitoring and protection circuits with AC rated voltage up to and including 0.6/1kV. and used in fixed installation and laying outdoor and indoor, direct burial, cable conduit and trench, etc.
STANDARD
IEC60502-1, or other standards required by customers
CONSTRUCTION
1.Conductor: plain or tinned copper wires, Class 1/Class 2/Class 5 as per IEC60228
2.Insulation: Polyvinyl Chloride (PVC)
3.Metallic screen(optional): copper wire braided (BCWB or TCWB), or copper tape(CTS), aluminum-polyester laminated tape(APLT)
4.Inner sheath (optional): Polyvinyl Chloride (PVC), or PE
5.Armour (optional): galvanized steel tape (DSTA), or round galvanized steel wire(SWA)
6.Outersheath: Polyvinyl Chloride (PVC), or PE
TYPICAL CABLE TYPE
Type |
Description |
KVV |
CU/PVC/PVC control cable |
KVVP |
CU/PVC/BCWB(TCWB)/PVC control cable |
KVVP2 |
CU/PVC/CTS/PVC control cable |
KVVP3 |
CU/PVC/APLT/PVC control cable |
KVVR |
CU/PVC/PVC flexible control cable |
KVVRP |
CU/PVC/BCWB(TCWB)/PVC flexible control cable |
KVVRP3 |
CU/PVC/APLT/PVC flexible control cable |
KVV22 |
CU/PVC/DSTA/PVC control cable |
KVV32 |
CU/PVC/SWA/PVC control cable |
KVVP22 |
CU/PVC/BCWB(TCWB)/PVC/DSTA/PVC control cable |
KVVP2-22 |
CU/PVC/CTS/PVC/DSTA/PVC control cable |
KVVP2-32 |
CU/PVC/CTS/PVC/SWA/PVC control cable |
KVVP3-32 |
CU/PVC/APLT/PVC/SWA/PVC control cable |
Number of cores |
Conductor sectional area (mm2) |
2 - 61 |
0.5, 0.75, 1.0 |
2 - 48 |
1.5, 2.5 |
2 - 14 |
4, 6 |
2 - 10 |
10 |
black with white numbers (without yellow/green earth core),
Green/yellow, black with white numbers (with yellow/green earth core),
Note: or other core identification method on request
SHEATH COLOR
Black,or other colour upon request
USAGE CHARACTERISTIC
Rated voltage: 0.6/1kV AC
Flame retardant: IEC60332-1.
The continuous operating temperature: 70℃
The maximum short circuit c temperature (maximum duration 5Ssec): 160℃
The minimum ambient temperature for installation: 0℃
The minimum bending radius of cable:
-12D for cable with armour and copper screen
-6D for cable without armour (D is the overall diameter of cable)
CERTIFICATION
CE Certifications
SPECIAL FEATURES ON REQUEST
Flame retardant: IEC60332-3 (Cat. A, B, C)
Fire resistant(MICA TAPE + PVC insulation): IEC60331
Anti-termite/anti-rodent protection
Use in low ambient temperature
UV resistant
Mineral oil resistant
PE insulation and/or PE sheath are available upon request