This cable is suitable for control, signal transmission, monitoring and protection circuits with AC rated voltage up to and including 450/750V. and used in fixed installation and laying outdoor and indoor, direct burial, cable conduit and trench, etc.
STANDARD:
GB/T 9330, AS/NZS 5000.3, or other standards required by customers
CONSTRUCTION:
1.Conductor: plain or tinned copper wires, Class 1/Class 2/Class 5 as per IEC60228
2.Insulation: Cross-linked Polyethylene (XLPE)
3.Metallic screen(optional): copper wire braided (BCWB or TCWB), or copper tape(CTS), aluminum-polyester laminated tape(APLT)
4.Inner sheath (optional): Polyvinyl Chloride (PVC), or PE or LSZH
5.Armour (optional): galvanized steel tape (DSTA), or round galvanized steel wire(SWA)
6.Outersheath: Polyvinyl Chloride (PVC), or PE, or LSZH
TYPICAL CABLE TYPE
Type |
Description |
KYJV |
CU/XLPE/PVC control cable |
KYJVP |
CU/XLPE/BCWB(TCWB)/PVC control cable |
KYJVP2 |
CU/XLPE/CTS/PVC control cable |
KYJVP3 |
CU/XLPE/APLT/PVC control cable |
KYJVR |
CU/XLPE/PVC flexible control cable |
KYJVRP |
CU/XLPE/BCWB(TCWB)/PVC flexible control cable |
KYJVRP3 |
CU/XLPE/APLT/PVC flexible control cable |
KYJV22 |
CU/XLPE/DSTA/PVC control cable |
KYJV32 |
CU/XLPE/SWA/PVC control cable |
KYJVP22 |
CU/XLPE/BCWB(TCWB)/PVC/DSTA/PVC control cable |
KYJVP2-22 |
CU/XLPE/CTS/PVC/DSTA/PVC control cable |
KYJVP2-32 |
CU/XLPE/CTS/PVC/SWA/PVC control cable |
KYJVP3-32 |
CU/XLPE/APLT/PVC/SWA/PVC control cable |
NUMBER OF CORES AND SIZE
Number of cores |
Conductor sectional area (mm2) |
2 - 61 |
0.5, 0.75, 1.0 |
2 - 48 |
1.5, 2.5 |
2 - 14 |
4, 6 |
2 - 10 |
10 |
CORE IDENTIFICATION:
black with white numbers (without yellow/green earth core),Green/yellow, black with white numbers (with yellow/green earth core),
Note: or other core identification method on request
SHEATH COLOR:
Black,or other colour upon request
USAGE CHARACTERISTIC:
Rated voltage: 450/750V AC
Flame retardant: IEC60332-1.
The continuous operating temperature: 90℃
The maximum short circuit c temperature (maximum duration 5Ssec): 250℃
The minimum ambient temperature for installation: 0℃
The minimum bending radius of cable:
-12D for cable with armour and copper screen
-6D for cable without armour (D is the overall diameter of cable)
CERTIFICATION:
CE Certifications
SPECIAL FEATURES ON REQUEST:
Flame retardant: IEC60332-3 (Cat. A, B, C)
Fire resistant(MICA TAPE + XLPE, silicone rubber insulated): IEC60331
Low smoke and halogen free to IEC61034, IEC60754
Anti-termite/anti-rodent protection
Use in low temperature (-40℃)
UV resistant
Mineral oil resistant
Thermosetting cross-linked LSZH XLPO insulation
CORE IDENTIFICATION:
black with white numbers (without yellow/green earth core),Green/yellow, black with white numbers (with yellow/green earth core),
Note: or other core identification method on request
SHEATH COLOR:
Black,or other colour upon request
USAGE CHARACTERISTIC:
Rated voltage: 450/750V AC
Flame retardant: IEC60332-1.
The continuous operating temperature: 90℃
The maximum short circuit c temperature (maximum duration 5Ssec): 250℃
The minimum ambient temperature for installation: 0℃
The minimum bending radius of cable:
-12D for cable with armour and copper screen
-6D for cable without armour (D is the overall diameter of cable)
CERTIFICATION:
CE Certifications
Flame retardant: IEC60332-3 (Cat. A, B, C)
Fire resistant(MICA TAPE + XLPE, silicone rubber insulated): IEC60331
Low smoke and halogen free to IEC61034, IEC60754
Anti-termite/anti-rodent protection
Use in low temperature (-40℃)
UV resistant
Mineral oil resistant
Thermosetting cross-linked LSZH XLPO insulation